Netzsch Technologies India Private Limited
Netzsch Technologies India Private Limited
Mogappair, Chennai, Tamil Nadu
Send SMS
Send E-mail

Differential Scanning Calorimetry

Our clients have inspired us to manufacture a wide range of Differential Scanning Calorimetry that has a very high demand in the market. These products are designed keeping in mind the special needs and requirements of our clients. Before these products are delivered to the clients, all its components are checked as per the international standards of quality. Highly beneficial for the medical industry, these products are used to observe fusion and crystallization events as well as glass transition temperatures.

Request CallBack
Phoenix DSC High Pressure Calorimeter
Ask For Price

Phoenix DSC High Pressure Calorimeter

Product Details:
ApplicationIndustrial, Laboratory

We have employed a team of skilled and trained professional who have the necessary acumen to provide our respected clients with a range of Phoenix DSC High Pressure. Our clients can avail from us these products in a customized form as per their need and requirements. These products are also tested thoroughly as per the international standards of quality.

 

The features are:

 

  • Superior quality

  • Optimum service

  • High performance

  • Long service life

  • Robust construction

  • Highly tensile

  • Low maintenance

  • Uniquely designed

  • Easy to operate

 

Technical Specifications

 

  • Wide pressure range: vacuum … 15 MPa (approx. 2176 psi)

  • Exact pressure adjustment: (e.g. 10 MPa ± 0.002 MPa)

  • Temperature range (depending on the gas type): „->“-150°C ... 600°C (at 1 bar) -90°C ... 600°C (at 50 bar) -50°C ... 450°C (at 150 bar)

  • Heating rates: 0.01 K/min ... 50 K/min

  • Measurements in different atmospheres: „->“- inert: N2, noble gases - reducing: H2

  • - oxidizing: O2, CO2, air, other gas types on demand

  • Exact gas flow regulation up to 500 ml/min

  • Exchangeable sensor plate

 

Application areas:

 

  • High-Pressure DSC (Differential Scanning Calorimeter) for the most varied applications

  • Oxidation


Additional Information:
  • Item Code: DSC204HP
Yes! I am interested
Request CallBack
High Temperature Differential Scanning Calorimeter
Ask For Price

High Temperature Differential Scanning Calorimeter

The DSC 404 F3 Pegasus®, High-Temperature Differential Scanning Calorimeter, is part of the economical NETZSCH F3-product line, which is specially tailored to the requirements of comparative material characterization and quality control.

The DSC 404 F3 Pegasus®, High-Temperature Differential Scanning Calorimeter, can be operated from -150°C to 2000°C with various DTA and DSC sensors that are easily exchangeable by the user and various furnace types (please see accessories).

The sample chamber can be purged with inert or oxidizing gases in order to remove gases evolved from the sample.

The measuring system is vacuum tight (10-4 mbar).


Yes! I am interested
Request CallBack

Differential Scanning Calorimeter (DSC)

Product Details:
BrandNETZSCH
We offer various DSC models, covering a broad temperature range from -180°C to 1750°C. The DSC 404 F1 and F3 Pegasus® are two versions for the precise determination of specific heat and caloric effects, particularly in the high-temperature range. The DSC 204 F1 Phoenix® is our premium device for the temperature range from -180°C to 700°C. It unites excellent performance and highest flexibility. Coupled to a UV add-on (Photo-DSC 204 F1 Phoenix®), it allows for monitoring the light-induced curing of, for example, paints, adhesives and resins. With the DSC 204 HP Phoenix®, measurements under increased pressure can be carried out (up to max. 150 bar). The DSC 214 Polyma is a completely new concept. Designed especially for the characterization of polymer materials, its integral approach consists not only of the DSC instrument alone, but also incorporates the entire analytical process chain from sample preparation to evaluation.
All differential scanning calorimeters discussed here operate based on the respective instrument standards as well as application or material testing specifications, including ISO 113587, ASTM E968, ASTM E793, ASTM D3895, ASTM D3417, ASTM D3418, DIN 51004, DIN 51007 and DIN 53765.
back to the diverse instrument models:
  • DSC 214 Polyma
  • DSC 3500 Sirius
  • DSC 204 F1 Phoenix®
  • Photo-DSC 204 F1 Phoenix®
  • DSC 204 HP
  • DSC 404 F3 Pegasus®
  • DSC 404 F1 Pegasus®

Ask For Price
Yes! I am interested
Save time! Get a Best Deal

*Your information is safe with us.

Request CallBack
DSC Differential Scanning Calorimeter
Ask For Price

DSC Differential Scanning Calorimeter

Product Details:
Minimum Order Quantity1 Piece
BrandNETZSCH
Model214 Polyma
MaterialPolymer, Plastic, Rubber, nano materials
ApplicationIndustrial

Our clients have inspired us to provide a wide range of DSC Differential Scanning Calorimeter that has a very high demand in the market. These products are stringently tested by our huge quality team in accordance to the standards followed globally. We can also customize these products as per the needs and demands of our clients. These products are equipped with newly developed monolithic DSC sensor and a new silver heater with long-life heating element.

The features are:

  • Superior quality
  • Optimum service
  • High performance
  • Long service life
  • Robust construction
  • Highly tensile
  • Low maintenance
  • Uniquely designed
  • Easy to operate

 

Technical Specification:

  • Temperature range: -170°C ... 600°C
  • Heating rates: 0.001 K/min ... 100 K/min
  • Cooling rates: 0.001 K/min ... 100 K/min (depending on temp.)
  • Sensor: heat flux system
  • Measurement range: 0 mW ... ± 600 mW
  • Temperature accuracy: 0.1 K
  • Enthalpy accuracy: generally < 1%
  • Cooling options: Forced air (down to RT), LN2 (down to -170°C)
  • Intracooler for the extended rate: -40° ... 600°C
  • New, more powerful intracooler, for faster cooling rates, for temperature range between -70 and 600°C
  • Atmospheres: oxid., inert (static, dynamic)
  • Automatic sample changer (ASC) for up to 20 samples and references (option)
  • Electronics: integrated TASC 414/6
  • PC Interface: USB

Applications areas:

  • Ethylene-Propylene-Diene-Rubber-Mixture (EPDM)
  • Polyethylene (PE)
  • Oxidative Induction Time (O.I.T.)
  • High-Temperature Applications
  • Curing of an Epoxy Resin

Additional Information:
  • Item Code: DSC200F3Maia
Yes! I am interested
Request CallBack
Modulated Differential Scanning Calorimeter
Ask For Price

Modulated Differential Scanning Calorimeter

Product Details:
Minimum Order Quantity1 Piece
BrandNETZSCH
Model204 F1 Phoenix
ApplicationIndustrial, Laboratory

We also offer a wide gamut of Modulated Differential Scanning Calorimeter to our respected clients. These products are manufactured using radically curing material systems and its main advantage is light-curing systems that ensures fast reaction time. We also provide our clients with a customized range of these fountains as per their requirements. Our team also tests these products as per the international standards of quality.

 

The features are:


  • Superior quality
  • Optimum service
  • High performance
  • Long service life
  • Robust construction
  • Highly tensile
  • Low maintenance
  • Uniquely designed
  • Easy to operate

 

Technical Specifications

 

  • Temperature range: -180°C ... 700°C
  • Wide range of heating rates: 0.001 K/min ... 200 K/min
  • Fast cooling: max. 200 K/min
  • Very short time constant with T-sensor
  • Extremely high sensitivity with µ-sensor
  • Base line optimization through Be-flat®
  • Gas tight measuring cell, ideal for coupling to FTIR or MS, even with automatic sample changer
  • Gas control for 2 sample gases and 1 protective gas through integrated mass flow controller and software
  • Compressed air cooling: RT ... 700°C
  • Intra-cooler for the extended range: -85°C ... 600°C
  • Automatically controlled liquid nitrogen cooling: -180°C ... 700°C
  • Automatic sample changer: DSC 204 F1 Phoenix® ASC for 64 samples and reference crucibles (optional)
  • UV-extension for photo-calorimetry (optional)

 

Application areas:

 

  • Polymers
  • UV curing
  • Metals
  • Pharmaceuticals

Additional Information:
  • Item Code: DSC204F
Yes! I am interested
Request CallBack
High Pressure Differential Scanning Calorimeter
Ask For Price

High Pressure Differential Scanning Calorimeter

Numerous physical processes and chemical reactions are influenced by the surrounding gas pressure. In practise it is therefore often necessary to conduct DSC measurements under an increased pressure.

With the high-pressure Differential Scanning Calorimeter, DSC 204 HP Phoenix®, thermal effects in a sample can be analyzed in the pressure range from vacuum to 15 MPa (150 bar) and at temperatures from -150°C to 600°C, depending on the type of gas.
The sample chamber atmosphere can be static or dynamic. The electronic pressure monitor and control, along with exact regulation of the purge gas flow, provide for excellent accuracy and reproducibility of the measurement results.
The proven CC 200 L for liquid nitrogen cooling is available for the low-temperature range.
The safety of the high-pressure DSC system has been certified through design tests and is guaranteed during operation by the appropriate safety components.


Yes! I am interested
Save time! Get a Best Deal

*Your information is safe with us.

Request CallBack
Phoenix Differential Photocalorimeter
Ask For Price

Phoenix Differential Photocalorimeter

Inspired by the positive feedback from our clients, we also supply a wide array of Phoenix Differential Photocalorimeter. These products are tested as per the international standards of quality. Customized forms of these products are also appreciated hugely by our clients. These products are specially used for research, development and quality assurance.

 

The features are:

 

  • Superior quality

  • Optimum service

  • High performance

  • Long service life

  • Robust construction

  • Highly tensile

  • Low maintenance

  • Uniquely designed

  • Easy to operate

 

Technical Specifications:

 

  • Temperature range: -100°C to 200°C

  • Crucibles: open Aluminum

  • Recommended Hg-Lamp types: DELOLUX 04, OmniCure® S 2000

  • Max. Power: 9.9 W/cm2, >10 W/cm2

  • Wavelength range: 280/315 nm to 500 nm*, 280/320 nm to 500 nm*

  • Irradiation time: 0.1 s to 1000 s, 0.2 s to 1000 s

  • Existing orifice diameter: 8 mm, 4 mm, 2 mm, 8 mm, 4 mm, 2 mm

  • Durability (Lamp): 1500 h, 2000 h

 

Application areas:

 

  • Paints

  • Dental Composites


Additional Information:
  • Item Code: DSC204F1
Yes! I am interested
Request CallBack

Polyma Differential Scanning Calorimeter

The DSC 214 Polyma delivers a powerful solution for requirements in day-to-day measuring tasks in terms of both hardware and software. It is easy to operate while still providing absolute reliability, making this innovative DSC instrument an ideal tool for the research, development, quality assurance and failure analysis of polymer materials.

Additional Information:
  • Item Code: DSC214
Ask For Price
Yes! I am interested
Request CallBack
DSC Pegasus High Temperature Calorimeter
Ask For Price

DSC Pegasus High Temperature Calorimeter

We are one of the leading manufacturer and supplier of a wide array of DSC Pegasus High Temperature Calorimeter. These products thermodynamic properties of ceramics and metallic high-performance materials and are crafted keeping in mind the various requirements and specifications of our clients. We stringently check these products as per the international standards of quality before it is delivered to the clients. These products are generally operated with high temperature ranging from -150°C 2400°C.

 

The features are:

 

  • Superior quality

  • Optimum service

  • High performance

  • Long service life

  • Robust construction

  • Highly tensile

  • Low maintenance

  • Uniquely designed

  • Easy to operate

  • Highest flexibility

 

Technical Specifications:

 

  • NEW: High-speed furnace (RT ... 1250°C)

  • The DSC cp sensors enable extremely accurate determination of the specific heat up to 1400°C

  • A graphite furnace with W/Re sensors for DTA measurements up to 2000°C is available

  • Extension with unique OTS™ system is available

  • An Automatic sample changer (ASC) for up to 20 samples and references is available (option)

 

Application areas:

 

  • Accuracy of specific heat determination of alumina (Al2O3)

  • Specific heat of volcanic rock

  • Phase transitions in an SAE 107 steel material


Additional Information:
  • Item Code: DSC404F
Yes! I am interested

Explore more products

X
Looking for “Differential Scanning Calorimetry”?