We have been instrumental in the manufacturing and supplying of Dilatometry Instruments that are valued highly by our respected clients. These products are checked thoroughly as per the international standards of quality before it is finally delivered to the clients. We are also known in the market for the customization of these products as per the requirements and specifications of the clients. These products are used for the measurement of thermal expansion and dilation in solids and liquids, which changes in the volume of a liquid or dimensions of a solid. 

Request CallBack
Dilatometry(DIL 402 Expedis Classic)
Ask For Price

Dilatometry(DIL 402 Expedis Classic)

Product Price : Get Latest Price
Product Details:
ApplicationLaboratory
Model Number/NameDIL402
FeaturesGas control
Measurement Range5000um
Temperature Accuracy1K
Sample Holder SystemSingle, Dual and Differential Sys
Displacement SystemNanoEye
Temperature Precision0.1K
Resolution2nm
SoftwareAvailable

With our vast industry experience, we have gained expertise in offering a wide gamut of DIL 402 PC-Horizontal Push Rod Dilatometer. The offered range is precisely manufactured by our professionals using excellent quality raw material and ultra-modern tools and technology at our sophisticated infrastructure premises.

 

The features are:

 

  • Superior quality

  • Optimum service

  • High performance

  • Long service life

  • Robust construction

  • Highly tensile

  • Low maintenance

  • Uniquely designed

  • Easy to operate

  • Low power consumption

 

Technical Specifications:

 

  • Temperature range: RT ... 1200°C, 1600°C (2 furnace types)

  • Heating and cooling rates: 0.01 K/min ... 50 K/min (dependent on furnace)

  • Sample holder:

  • fused silica <1100°C

  • Al2O3 <1600°C

  • Measuring range: 500/5000 µm

  • Sample length: max. 50 mm

  • Sample diameter: max. 12 mm

  • Δl resolution: 8 nm

  • Atmospheres: oxidizing: static and dynamic, inert: dynamic

  • Gas flow controller for purge gas (optional)

  • c-DTA® for the calculated DTA-signal from dilatometer measurements, ideal for temperature calibration (optional)

  • Integrated electronics

  • USB interface for PC connection

 

Application areas:

 

  • Accuracy: Polycrystalline Alumina

  • Glass

  • Sintering of Zirconia

  • Production of Cordierite Ceramic


Additional Information:
  • Item Code: DIL-402-PC
Yes! I am interested
Request CallBack
DIL 402 Expedis Select & Supreme
Ask For Price

DIL 402 Expedis Select & Supreme

Product Price : Get Latest Price
Product Details:
Minimum Order Quantity1 Piece
BrandNETZSCH
Model402 Expedis Select & Supreme
Raw MaterialCeramic
ApplicationIndustrial

The new dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.

It is the first horizontal dilatometer series on the market which allows for force modulation and, by this means, bridges the gap between dilatometry and thermomechanical analysis (TMA) under oscillatory load. 

The features are:

  • Superior quality

  • Optimum service

  • High performance

  • Long service life

  • Robust construction

  • Highly tensile

  • Low maintenance

  • Uniquely designed

  • Easy to operate

  • Low power consumption

 

Technical Specifications:

  • Temperature range: -180°C ... 500°C, RT ... 1600°C, (RT) ... 550°C ... 2400°C, (RT) ... 650°C ... 2800°C (exchangeable furnace types)

  • Heating and cooling rates: 0.01 K/min ... 50 K/min (dependent on furnace and temperature range)

  • Sample holder:

  • fused silica <1100°C

  • Al2O3 <1700°C

  • graphite 2800°C

  • Measuring ranges: 500/5000 µm

  • Sample length: 25/50 mm

  • Sample diameter: max. 12 mm

  • Δl resolution: 0.125 nm / 1.25 nm

  • Atmospheres: inert, oxidizing, reducing, static and dynamic

  • Gas flow meter and valve for purge gas (optional)

  • c-DTA® for the calculated DTA-signal from dilatometer measurements, ideal for temperature calibration (optional)

  • Highly vacuum-tight up to 10-4 mbar (10-2 Pa)

  • Coupling to QMS 403 C Aëolos® over a heatable adapter at the exit of the furnace


Yes! I am interested
Request CallBack
DIL 402 Expedis HT
Ask For Price

DIL 402 Expedis HT

Product Price : Get Latest Price
Product Details:
ApplicationLaboratory
  • Broadest Application Range

    Two graphite furnaces with end temperatures of 2400°C and 2800°C provide the appropriate configuration for measuring the thermal expansion of metals, alloys, ceramics and composites in applications such as aerospace, power generation, the oil and gas industry or demanding research.

    However, via an adapter, each of these graphite furnaces can be replaced with a standard furnace such as SiC, SiO2, Cu or steel. The opposite is also feasible: A DIL 402 Expedis Supreme HT measuring part with a standard furnace can be subsequently retrofitted with a high-temperature furnace.

  • Pyrometer for Detection of the Highest Temperatures
       Since W-Rh thermocouples can react with graphite above           2000°C, the sample temperature of the DIL 402 Expedis             Supreme HT is measured optically with a high-   performance pyrometer from room temperature onward.

 


Yes! I am interested
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
High Temperature Version
Ask For Price

High Temperature Version

Product Price : Get Latest Price
Product Details:
ApplicationLaboratory
Broadest Application Range

Two graphite furnaces with end temperatures of 2400°C and 2800°C provide the appropriate configuration for measuring the thermal expansion of metals, alloys, ceramics and composites in applications such as aerospace, power generation, the oil and gas industry or demanding research.

However, via an adapter, each of these graphite furnaces can be replaced with a standard furnace such as SiC, SiO2, Cu or steel. The opposite is also feasible: A DIL 402 Expedis Supreme HT measuring part with a standard furnace can be subsequently retrofitted with a high-temperature furnace.


Additional Information:
  • Item Code: DIL-402
Yes! I am interested